Example:
PSES-2126C(802.1x)# set reAuthMax 2 2
쮿 set reAuthPeriod
Syntax:
set reAuthPeriod <port-range> <sec>
Description:
A constant that defines a nonzero number of seconds between periodic
reauthentication of the supplicant.
Argument:
<port range> : syntax 1,5-7, available from 1 to 26
<sec> : timer, range 1-65535
Possible value:
<port range> : 1 to 26
<sec> : 1-65535, default is 3600
Example:
PSES-2126C(802.1x)# set reAuthPeriod 2 3600
쮿 set serverTimeout
Syntax:
set serverTimeout <port-range> <sec>
Description:
A timer used by the Backend Authentication state machine in order to
determine timeout conditions in the exchanges between the
Authenticator and the Supplicant or Authentication Server. The initial
value of this timer is either suppTimeout or serverTimeout, as determined
by the operation of the Backend Authentication state machine.
Argument:
<port range> : syntax 1,5-7, available from 1 to 26
<sec> : timer, range 1-65535
Possible value:
<port range> : 1 to 26
<sec> : 1-65535, default is 30
Example:
PSES-2126C(802.1x)# set serverTimeout 2 30